Drywall fitout — Melbourne CBD

Falomer delivers commercial-grade drywall fitouts across the CBD: expert partitioning, fire-rated systems, acoustic solutions and seamless finishing for modern interiors.

  • Services: Partition walls, suspended ceilings, bulkheads, fire-rated linings, acoustic lining
  • Typical clients: Offices, retail, hospitality, strata refurbishments
  • Coverage: Melbourne CBD and greater Victoria
Request a quoteCall +61 43 729 0518FAQ
Drywall fitout on-site

Project overview

Scope

Full drywall fitout for a 2-level office refurbishment in Melbourne CBD. Works included stud framing, plasterboard installation, fire-rated linings, tapered joints and skim, plus bulkhead and ceiling systems.

  • Fire-rated partitions (up to FD60)
  • Acoustic partitions STC 55+
  • Moisture-resistant linings for wet-areas
Discuss scope
Drywall detailed view
Delivery

Phased delivery to match tenant fitout schedule. We coordinate with MEP trades and supply certified materials for compliance.

Services & Systems

Partition Walls

Metal stud systems with multiple board layers for acoustic and fire performance.

Ceilings & Bulkheads

Standard and acoustic ceilings, bulkheads for services, integrated downlights and diffusers.

Fire & Acoustic Linings

Certified fire-rated systems and acoustic linings to meet project specifications and BCA requirements.

Project team

Project manager
Liam Carter — Project Manager

Oversees site delivery, compliance and client coordination for commercial fitouts across the CBD. Contact via the office to discuss site inspections.

Call LiamBook inspection

Typical process

01

Site survey & scope

02

Design coordination

03

Installation

04

Handover & defects

FAQ

Small to medium partitions for an office floor typically 2–4 weeks depending on scope; larger multi-zone works are phased to schedule.

Yes — we install BCA-compliant fire-rated linings and supply certification details for each system installed.

Yes—where site rules permit, we offer night/weekend work to meet tenant timelines with prior arrangement.

Standards & compliance

Falomer adheres to Australian standards for plasterboard installation, BCA requirements for fire and acoustic performance, and maintains public liability and workers' insurance for all projects.

Item Standard Notes
Fire linings AS 1530 / BCA Tested systems with certification
Acoustic partitions AS/NZS ISO 717 STC ratings on request
Installation Manufacturer instructions Certified installers

Ready to start your fitout?

Contact Falomer for a site assessment and a tailored scope & quote.